How much cost to heat your INDUSTRIAL BUILDING/SHOP?

Table to calculate the power and equipment to provide heating service, depending on the square meters and the minimum outdoor temperatures, with ete technology to produce heat, using electricity:
Model
Power
Square meters of a home, building, comercial office, ceiling height of 2,60m - according to minimum outdoor temperatures
Heating
Heating + Hot Water
kW
-5°C
-3°C
0°C
5°C
Q-4E
M-3
4,5 (230V o 400V III)
110
120
135
150
Q-6E
M-6
7,5 (230V o 400V III)
180
190
227
250
Q-9E
M-9
10,5 (230V o 400V III)
260
285
320
350
Q-10E
M-10
12 (230V o 400V III)
300
325
365
400
Q-13E
M-13
15 (230V o 400V III)
370
410
454
500
C-15
M-15
18 (230V o 400V III)
440
486
545
600
C-18
M-18
21 (230V o 400V III)
515
570
635
700
C-20
M-20
24 (230V o 400V III)
585
650
727
800
C-23
M-23
27 (230V o 400V III)
660
730
820
900
C-25
M-25
30 (230V o 400V III)
730
810
909
1000
C-30
M-30
36 (230V o 400V III)
878
972
1100
2000

Determine the minimum winter outdoor temperature in your area, look at the outdoor temperature column: -5ºC; -3ºC; 0ºC and + 5ºC.

Once in the column you have selected, find the square meters of your home.

Once located in the square meters of your home, scroll to the left and you will see the power you need and the heat production equipment, there are two columns, one for heating equipment and the other for heating equipment and sanitary hot water for bathrooms and kitchen.

Do not be surprised if the power shown in the table does not match the power of your combustion boiler or your old electric boiler, it is normal for our equipment to have a much lower power.

As you can see, the powers of 4.5kw and 7.5kw can be supplied to connect to 230V II or 400VIII, depending on the electrical installation you have, the rest of the powers connect to 400VIII, which is a normal voltage in large homes.

Exchanging the old boiler for high-tech ete equipment is easy, a plumber and a local electrician can do the installation in one working day.

If you want to calculate the consumption you will have in the coldest month, determine the hours that you usually have heating, for example if you turn on the heating from 2:00 p.m. to 10:00 p.m. It gives us a time of 8 hours a day, if you multiply 8 by the power of the equipment it will give you the consumption in kW of the coldest days, multiplying this consumption by 30 days will have the expense of the coldest month. To further refine the calculation multiply the consumption of the month by 0.70 to make a more real calculation of the kW consumed during that month and as you will have the price of the kWh on your receipt multiply the kWh of the month by that price and you will have the cost of the coldest 3 months and the other three months the cost will be approximately 50%.

When you compare the cost of the entire heating season with the cost you currently have you will see that consumption is reduced by more than 50% and you will also have better service and more security.

I want to give an example of a heating and hot water installation in a 170m2 house with 2.6m ceilings in the Sierra de Madrid, with temperatures of -5ºC and an 8-hour daily heating program, the annual cost of diesel was € 2100 plus € 200 maintenance costs, the cost they currently have for 6 months of heating is about € 750.

I specify that the electric boiler must be of the ete brand because it is common when calculating electric boilers of other brands to install 30 kW electric boilers to heat the same surface.

ete electric boilers can replace any type of electric or combustion boiler, the replacement can be done by any plumber with the support of the electrician who installs the power supply cable.

When you consult the ete technicians, they will provide you in writing with all the information you need to make a safe boiler change decision with a 10-year warranty.

10 YEAR WARRANTY - SIMPLE INSTALLATION - MINIMUM MAINTENANCE

Model Sol (Only Heating)

Model
Power kW
Power kcal/h
Voltage
Q-4E
4,5
3.870
230 VII / 400 VIII
Q-6E
7,5
6.450
230 VII / 400 VIII
Q-9E
10,5
9.030
400 VIII
Q-10E
12
10.320
400 VIII
Q-12E
15
12.900
400 VIII

Model Blanca (Only Heating)

Model
Power kW
Power kcal/h
Voltage
C-15
18
15.480
400 VIII
C-18
21
18.000
400 VIII
C-20
24
20.640
400 VIII
C-23
27
23.220
400 VIII
C-25
30
25.800
400 VIII
C-30
36
30.960
400 VIII

Model Calas (Combi Boiler: hot water and heating)

Model
Power kW
Power kcal/h
Voltage
M-3
4,5
3.870
230 VII / 400 VIII
M-6
7,5
6.450
230 VII / 400 VIII
M-9
10,5
9.030
400 VIII
M-10
12
10.320
400 VIII
M-13
15
12.900
400 VIII
M-15
18
15.480
400 VIII
M-18
21
18.060
400 VIII
M-20
24
20.640
400 VIII
M-23
27
23.220
400 VIII
M-25
30
25.800
400 VIII
M30
36
30.960
400 VIII